FR58L4M32-4020S(A)

FR58L4M32-4020S(A)

FR58L4M32-4020S(A) presence sensing radar sensor module is a high-performance 5.8G radar sensor launched by Fei Rui Intelligent, the module size is 40*20mm, the chip integrates 5.8G microwave circuit, intermediate frequency amplifier circuit and signal processor, high integration And the production consistency is good, and the peripheral is equipped with a low-noise LNA and dual transceiver antennas, which greatly improves the sensing performance of the sensor. The module can be applied to scenes such as human breathing detection in conference rooms.

Features

The radar module has a long sensing distance, wide angle, no dead zone, and lens and lens aging problems are not affected by temperature, humidity, airflow, dust, noise, brightness, and so on. It is widely used in smart lighting, smart security, smart home appliances, smart home, vital signs and other fields. It can detect human micro-motion and breathing signals, realize living detection under human motion and static state, and realizing presence sensing .

Parameter

parameter

Small value

Typical value

Large value

Company

remarks

Emission frequency

5725

5800

5875

MHz

output voltage

4.5

5

5.5

V

Output high level

5

V

Output low level

0

V

Working current

33

mA

Sensing distance

2.5

M

Human presence induction

Sensing distance

4

M

Human micro motion sensing

Delay Time

2

S

Specific requirements are adjustable

Photosensitive threshold

N/A

Optional, no photosensitive paste by default

Beam angle

120

°

Antenna related

working temperature

-30

85

Storage temperature

-50

125

Packing description

1. The module is packed in a blister box and placed in a blister box;

2. The blister boxes are stacked in a cardboard box according to 10 boxes;

3. The air raid in the carton is filled with instant noodles to reduce transportation abrasion;

4. Air bubble film is placed at the bottom of the carton to prevent abrasion during transportation;

5. The top layer is covered with bubble film and taped to prevent shaking.

3.png

Installation Precautions

· Avoid installing metal accessories or shells, metal will block the microwave and affect the effect;

· The antenna surface should be protected from high-current circuit coverage, which may cause interference;

· The output current of the sensor is very weak, and driving too large current is likely to cause false alarms. You can use the isolation drive method to drive the load, and use the OUT pin to read the status of the output port;

· Please use a power supply with low ripple for power supply, especially low-frequency ripples that easily interfere with the operation of the sensor. It is recommended that the power supply capacitor be larger than 100uF, and the recommended installation distance of the sensor is greater than 1.5m;

· The installation process of the product requires keeping the antenna board at a certain height away from the metal plane, and not close to or touching the metal plane, otherwise the product may not work normally;

· Avoid installing metal accessories or enclosures. Metal will block microwaves and affect the effect; therefore, this product should not be installed in a metal enclosure for use. However, the penetration effect is better for obstacles such as plastic, ceramics, and wood soil;

· Please use a power supply with a small ripple for power supply, especially low-frequency ripples are likely to interfere with the operation of the sensor. It is recommended that the power supply capacitor be larger than 100uF;

· The output current of the sensor is very weak. Excessive current driving is likely to cause false alarms. The load can be driven by an isolated driving method, and the output port status can also be read by MCU;

· When multiple sensors are used in the same site, it is recommended that the product installation distance be greater than 1.5m. Too close the installation distance may cause false alarms in individual cycles;

· The antenna surface should be protected from high-current circuit coverage, which may cause interference.

· Warning: The intermediate frequency signal output port (IFI/IFQ) is sensitive to ESD (electrostatic damage). Contact with high static electricity areas or power supply areas may cause irreversible damage to the radar module.

· Recommendation: It is recommended to use a qualified DC stabilized power supply, that is, a DC stabilized power supply whose output voltage, current and ripple coefficient meet the standards, otherwise it will affect the stability of the product and some abnormalities may occur, such as: false alarms, no Induction, circulation, self-starting, etc.

主站蜘蛛池模板: 青青草久久 | 一区二区三区 | 在线免费看毛片 | 国产999精品久久久久久 | 二区国产 | 国产亚洲精品精品国产亚洲综合 | 午夜精品久久久 | 最近中文字幕视频在线观看 | 91 久久 | 欧美一区二区 | 国产一区二区h | 深夜影院一级毛片 | 男女av | 欧美日韩亚洲在线观看 | 色姑娘综合色 | 正在播放国产精品 | 亚洲天堂偷拍 | 国产免费小视频 | 日韩一区欧美一区 | 久久免费视频网 | 久久精品国产一区二区三区 | 国产成人精品一区二区三区视频 | 精品久久久久久久久久久院品网 | 欧美一级二级三级 | 色综合热 | 逼逼网 | 亚洲色图第一区 | 不卡二区| 久久国产精品影视 | 国产精品一区二区6 | 国内精品国产成人国产三级粉色 | 青青av| 国产精品成人免费视频 | 日韩精品一区在线观看 | 国产精品一区二 | 日韩成人影片 | 国产91一区二区三区 | 淫伦小说短篇合集 | 亚洲一区二区高潮无套美女 | 国产露脸精品产三级国产 | 欧美日韩国产中文字幕 |